Manufacturing Tolerances for Insulated Metal Panels
Length Up to 20 ft: ± 1/8 in.
Over 20 ft.: ± 3/16 in.Width ± 1/8 in.
Thickness ± 1/8 in.
Squareness ± 1/8 in. (measured 6 in. from end)
Lateral Bow
- Up to 10 ft. ± 3/32 in.
- 10 ft. to 20 ft.: ± 3/16 in.
- Over 20 ft.: ± 3/8 in.
Flatness ± 3/16 in. per 2 ft. span
Joints
- Male/female joint edges flush, with not more than 1/8 in. deviation